cwejman
ctg-vc complex transient generator
price : $600.00
|

|
the envelope generator provide control voltages that can be used for dynamic change of all voltage controlled parameters, such as; frequency, amplitude, pulse width, cutoff. the most common use is controlling
filters cutoff frequency and a voltage controlled amplifiers amplitude in order to achieve dynamic timbre- and level-changes. all parameters such as attack time, attack hold time, decay time, sustain level,
release time and output level are voltage controlled.
the ctg-vc is a complex transient generator with a lot of features, such as; two different shapes for the attack, attack hold (a-hold) for more punchier sound than a standard attack, variable decay slope
(d-slope) from natural exponential to heavy logarithmic, attack-decay loop (a-d loop) and polarized level for outgoing transient signals which means that both outputs levels are controllable in both directions
(positive and negative). a-d loop switch activates, when on, a steady state attack/dacay generator and the rate is determinated by attack/decay time and attack/decay modes. the external signal alone in to the
a-d restart input start a single a-d transient for every new external signals a-d restart period (every shape). the sustain level should be in pos. 0. zero restart resets (when on) the remaining release
voltage for new gate signal so attack starts always from 0.
attack:
attack time is controlled manually and by an external signal. it has two shapes; logarithmic and exponential, controlled manually by a switch.
attack hold:
attack hold time is controlled manually and by an external signal.
decay:
decay time time is controlled manually and by an external signal.
d-slope:
decays shape is controlled manually, from exponential to logarithmic.
sustain:
sustain level is controlled manually and by an external signal
release:
decay time time is controlled manually and by an external signal.
performances:
attack time: 0.05 msec to 10 seconds
attack mode: logarithmic/exponential (exp), switched
a-hold: 0.5 msec to 2 seconds
a-d loop : on; continious lfo, attack/decay or activated by an external signal
decay time: 0.5 msec to 20 seconds
decay slope: exponential to logarithmic, manual
sustain level: 0 to 5 volts
release time: 0.5 msec to 20 seconds
outputs: 5 thru 0 to -5 volts, normal polarized, -5 thru 0 to 5 volts, inverted polarized
inputs:
gate/trig: 2 volts threshold, any waveform
a-d loop: 2 volts threshold, any waveform
level: 5 to -5 volts
attack: 0 to 5 volts
a-hold: 0 to 5 volts
decay: 0 to 5 volts
sustain: 0 to 5 volts
release: 0 to 5 volts
current 70ma
dimensions 128.4mm (h), 70.7mm (b), 3 he, 14te
for more information, please view this pdf file.
please click here to visit the manufacturer's webpage for more info.
|